A novel method to measure the energy efficiency and performance of an auto-cascade refrigeration cycle
Elsevier (2023-10)Auto-cascade refrigeration systems are the most used cycles to maintain spaces at ultra-low temperature conditions (-80 to −60 °C). The interest in these systems has risen due to the need to maintain and distribute COVID-19 ... -
Alternative CO2-based blends for transcritical refrigeration systems
Elsevier (2023-03-21)The extensive use of CO2 in commercial refrigeration system has grown in the last two decade thanks to the development of new components and configurations that allows working in transcritical conditions efficiently. ... -
ANN Modeling to Analyze the R404A Replacement with the Low GWP Alternative R449A in an Indirect Supermarket Refrigeration System
MDPI (2021-11-30)Artificial neural networks (ANNs) have been considered for assessing the potential of low GWP refrigerants in experimental setups. In this study, the capability of using R449A as a lower GWP replacement of R404A in ... -
Comparative study of transcritical vapor compression configurations using CO2 as refrigeration mode base on simulation
Elsevier (2013-03)Despite of the excellent efficiency of the CO2 transcritical cycle in heat pump mode, there is a loss of efficiency in refrigeration mode compared with the subcritical vapor compression cycle with HFC refrigerants. This ... -
Energy, Exergy, and Environmental (3E) Analysis of Hydrocarbons as Low GWP Alternatives to R134a in Vapor Compression Refrigeration Configurations
MDPI (2021-07-05)The phase-down of hydrofluorocarbons and substitution with low global warming potential values are consequences of the awareness about the environmental impacts of greenhouse gases. This theoretical study evaluated the ... -
Experimental analyis of energy performance of modified single-stage CO2 transcritical vapour compression cycles based on vapour injection in the suction line
Elsevier (2012-12)This work presents the experimental evaluation of the energy performance of a modified single-stage CO2 transcritical refrigeration plant with an internal heat exchanger (IHX) based on vapour injection in suction line. ... -
Experimental assessment of a thermoelectric subcooler included in a transcritical CO2 refrigeration plan
Elsevier (2022-05-25)This study brings an experimental research that has tested a real transcritical CO2 vapor compression cycle that includes a thermoelectric subcooler at the exit of the gas-cooler of the refrigeration plant. The aforementioned ... -
Experimental determination of the optimum intermediate and gas-cooler pressures of a commercial transcritical CO2 refrigeration plant with parallel compression
Elsevier (2021-05-05)CO2 systems used in refrigeration are becoming more complex with the aim of improving their energy performance. Parallel compression is one of the implemented solutions to enhance the performance of the plants. However, ... -
Experimental determination of the optimum working conditions of a transcritical CO2 refrigeration plant with integrated mechanical subcooling
Elsevier (2020-02-05)Subcooling methods for transcritical CO2 plants are being studied in order to improve their behavior. Among them, the Integrated Mechanical Subcooling system is one of the most promising owing that performs with high ... -
Experimental evaluation of alternative CO2-based blends for transcritical refrigeration systems
International Institute of Refrigeration (IIR) (2023-08-21)This work presents two refrigerant CO2 blends with R32 and R1270 designed with a theoretically nonflammability and a GWP below 150. Both mixtures were tested in a small-capacity vapour compression system with and without ... -
Experimental evaluation of different refrigeration system configurations using CO2-based blends as refrigerants
International Institute of Refrigeration (IIR) (2023-08)Recently, blends created by mixing CO2 with another fluid with a higher critical temperature are being considered, to allow subcritical operation at high outdoor temperature, thus increasing the COP. The goal of this ... -
Experimental evaluation of the CO2-based mixtures CO2/R32, CO2/R1234yf and CO2/R1270 in a transcritical refrigerating plant considering the effect of the internal heat exchanger (IHX)
Elsevier (2024-01-05)Using CO2 mixtures results in a simple but effective solution to increase the critical temperature of CO2 and reduce its working pressures. However, the overall effect of these mixtures on the global performance of the ... -
Experimental results of a high-temperature heat pump prototype with R1336mzz(Z) for various production temperatures
International Institute of Refrigeration (IIR) (2023-08) -
Improvements in the cooling capacity and the COP of a transcritical CO2 refrigeration plant operating with a thermoelectric subcooling system
Elsevier (2019-06-05)Restrictive environmental regulations are driving the use of CO2 as working fluid in commercial vapour compression plants due to its ultra-low global warming potential (GWP100 = 1) and its natural condition. However, at ... -
Influence of operational modes of the internal heat exchanger in an experimental installation using R-450A and R-513A as replacement alternatives for R-134a
Elsevier (2019-12-15)This paper presents a first and second law of thermodynamics study using experimental data from a medium capacity refrigeration system using R-450A, R-513A and R-134a as working fluids and an internal heat exchanger (IHX) ... -
Influence of subcooling in R449A supermarket low-temperature refrigeration circuit using medium temperature cooling load
Institut International du Froid (2023-04-05)This work studies the impact of subcooling in supermarket refrigeration systems with medium and low-temperature requierementsbased on a vapor compression single-stage with a subcooler. -
New positions for an internal heat exchanger in a CO2 supercritical refrigeration plant. Experimental analysis and energetic evaluation
Elsevier (2014-02)IHX is probably, one of the most commonly alternative used to improve cooling capacity and COP in a CO2 refrigerating plant working in supercritical conditions. The “classical” position at gas-cooler exit has been analyzed ... -
Performance assessment of an experimental CO2 transcritical refrigeration plant working with a thermoelectric subcooler in combination with an internal heat exchanger
Elsevier (2022-07-19)Regulations in the refrigeration sector are forcing the transition to low global warming potential fluids such as carbon dioxide in order to decrease direct greenhouse gases emissions. Several technologies have arisen over ... -